Single Phase, 120 VAC, 15 Amp, 1800W
Shift Controls full featured integrated temperature control panels feature industry leading control, integration, and safety. All panels are manufactured in the United States with the highest quality components and construction standards.
Applications: ISPA series temperature control panels are ideal for controlling 120 Volt heat trace and heat cable, immersion heaters, process heaters, gas preheaters, retort and muffle furnaces, and other resistive heaters.
Applications: ISPA series temperature control panels are ideal for controlling 120 Volt heat trace and heat cable, immersion heaters, process heaters, gas preheaters, retort and muffle furnaces, and other resistive heaters.
ELECTRICAL SPECIFICATIONS
|
|
Voltage | 120 VAC |
Frequency | 60 Hz |
Phases | Single |
Full Load Current Rating | 15 Amps |
Power Rating | 1800 W |
Power Controller | SSR (Zero-Cross) |
Short Circuit Current Rating (SCCR) | 100kA |
CONTROLLER FEATURES AND CONTROL SYSTEM INTEGRATION
|
|
Digital Temperature Controller | Advanced PID Controller with Autotuning, Temperature Ramping and Programmable Profiles, 10-Segment LED Power Output Display, Color Changing Display Face when in Alarm, Temperature Filtering |
Front Panel Mounted SAFE/RUN Switch | When the control switch is in the SAFE position, Controller is set to Stop mode and the Safety Contactor is Opened |
MODBUS Interface | Addressable RS-485 MODBUS Communication (RTU or ASCII) Data Register Tables and Communication Protocols are Detailed in the Manual |
Analog Temperature Retransmit | 4-20 mA Sourcing Signal Available Through Terminal Blocks |
Programmable Over-Temperature Alarm/Status | 250VAC, 5 Amp, Dry-Contact, Normally Open Relay Contact Available Through Terminal Blocks |
Optional Remote Enable | 24 VDC or 120 VAC Interlock Relay Available |
SAFETY
|
|
Electrical Construction | All Internal Terminals and Components are Finger-Safe (IP20) Electrical Design and Construction Excced NEC and UL-508A Standards |
Main Power Fusing | Class CC Fast Acting Fuse Included Disconnecting and Indicating Fuse Holder |
Control Power Fusing | 1 Amp 5x20mm Glass Fast Acting Fuse Included Disconnecting and Indicating Fuse Holder |
Heater Load Disconnect- Safety Contactor Opens Upon |
Overtemperature Condition - Programmable and Latching Front Panel Safe/Run Switch Placed in Safe Position Open Thermocouple or Open Sensor Optional External Interlock |
Factory Acceptance Testing | Fully Inspected and Tested Under Load Before Shipment |
Agency Approvals | All Components are UL Listed or Recognized |
CONSTRUCTION
|
|
Components | Securely Mounted with Grounded DIN Rail Mounts Name Brand American and German Manufacturers |
Wiring Connections | Labeled Terminal Blocks Used for Wiring Connections Wires Terminated with Ferrules or Spade Ends, Clearly Labeled with Wire Numbers Corresponding to Included Wiring Diagrams |
Enclosure | 11.9" x 10.2" x 5.9" (H x W x D) |
ENVIRONMENTAL SPECIFICATIONS
|
|
Enclosure Material | Polycarbonate Enclosure with Stainless Steel Hardware |
Environmental Rating | NEMA 4X Washdown Rated, IP66 |
Ambient Temperature Rating | 32 to 95°F (0 to 35°C) Indoor Use Only |
Storage Temperature Range | -4°F to 149°F (-20°C to 65°C) |
Relative Humidity | 10-85% Non-Condensing |
Altitude | 2000m or less |
Shift Controls is committed to producing a product where safety is paramount. We realize safety directly corresponds to meticulous design, selecting the highest quality components, and demanding perfection in construction.
FRONT PANEL SAFE/RUN SWITCH
|
A two-position RUN/SAFE selector switch allows an operator to place the temperature control panel in SAFE mode when not in use. This de-energizes the safety contactor and places the controller in a STOP mode. |
SAFETY POWER CONTACTOR
|
Power is physically disconnected from the heater by an electromechanical contactor when the following occurs: • The SAFE/RUN Switch is placed in the SAFE position
This feature ensures power is disconnected from the heater to protect personnel and equipment during a fault, over-temperature condition or when not in use.• An over-temperature condition occurs (PV > ALARM Temp) • A sensor fault occurs (ex. thermocouple becomes disconnected) • The optional external interlock relay is de-energized |
CURRENT-LIMITING MAIN BRANCH FUSING
|
All panels feature current-limiting fusing which comply with main branch power distribution requirements. The current-limiting specification limits the energy released during an over-current condition and allows the panel to be rated with an industry leading Short Circuit Current Rating (SCCR) of 100 kA. |
FINGER-SAFE (IP2X) CONSTRUCTION
|
The interior of the panel is designed and constructed to be fully finger-safe (IP2X) which can reduce the risk of accidental contact with energized parts during OSHA and NFPA 70E allowable energized work. |
QUALITY COMPONENTS AND CONSTRUCTION
|
All components are manufactured by industry leading name brands and are UL Listed or UL Recognized. The panel design complies with or exceeds UL508A and NEC Electrical Codes. All wires and terminal blocks are clearly labeled and numbered according to the included detailed wiring diagrams. Control wiring is separated from the main power wiring, through fuse protection, reducing risk to the user and connected systems. |
Shift Controls understands having the right options available reduces installation time and costs. We are committed to providing your temperature control panel with the options you need for easy installation, commissioning, and operation.
Below are the factory available options, feel free to contact our technical team for any other option or configuration. We will be happy to provide a customized solution for you.
Below are the factory available options, feel free to contact our technical team for any other option or configuration. We will be happy to provide a customized solution for you.
LINE AND LOAD POWER CONNECTION
|
|
Internal DIN Mount Screw Terminal Blocks - Line and Load (Standard) | Line and load wiring is connected to the panel by screw terminal blocks. This option provides the greatest flexibility in either conduit or corded installations. |
15 Amp Power Cord (Optional) | Line and load wiring, connected from the factory, using a heavy duty power cord. 5 foot plug and 5 foot receptacle cord length. |
15 Amp GFI Power Cord (Optional) | Line and load wiring, connected from the factory, using a heavy duty power cord with integral GFI outlet. 12 foot plug and 12 foot receptacle cord length. |
EXTERNAL REMOTE ENABLE/INTERLOCK RELAY
|
|
Add the ability to remotely enable and disable the temperature control panel. When the Enable/Interlock Relay coil is energized, the safety power contactor is energized and the controller is put into RUN Mode. | |
Factory Stocked Options | 24 VDC Coil, 120V VAC Coil |
INPUT SENSOR TYPE
|
|
Factory Stocked Options |
Thermocople Type: K, J |
Factory Custom Options (Typically 7-Day Lead-Time) |
Thermocouple Type: T, E, N, R, S, B, L, U, TXK RTD: JPt100, Pt100, Ni120, Cu50 Analog: 0-50mV, 0-5V, 0-10V, 4-20mA, 0-20mA |
INPUT SENSOR CONNECTION
|
|
Internal DIN Mount Bi-Metal Screw Terminal Block | A thermocouple screw terminal block option, mounted internal to the panel for easy sensor installation. |
External Standard Size Thermocouple Jack Panel Connector | An externally accessible thermocouple connector option, allowing thermocouples to be swapped easily and quickly. |
Factory Custom Options (Typically 7-Day Lead Time) | Contact our factory for other sensor connection options. This can be helpful in ensuring standardization of connectors across your facility. We can provide a customized solution upon request. |
MAIN BRANCH FUSE SIZE
|
|
Panel Maximum Rated Fuse Size (Standard) |
Main fuse protection of heater loads should be sized to at least 125% and not more than 160% (power controller manufacturer recommendation) of the heater's full load current. Panels will include a set fuses sized for the panel maximum allowable current. |
Factory Custom Options (Typically 5-Day Lead Time) |
Choose to include another fuse size from the drop down menu. |
SPECIFICATION SHEETS AND MANUALS
|
Temperature Control Panel Spec Sheet |
Quick Reference Guide (For Controller) |
Fuse Sizing Diagram and Table |
User Manual (Complete) |
WIRING DIAGRAMS
|
Wiring Diagram with TC Terminal Block |
Wiring Diagram with TC Terminal Block, External Interlock |
Wiring Diagram with TC Terminal Block, External Interlock, SO Cord |
Wiring Diagram with TC Terminal Block SO Cord |
Wiring Diagram with TC Jack Panel |
Wiring Diagram with TC Jack Panel, External Interlock |
Wiring Diagram with TC Jack Panel, External Interlock, SO Cord |
Wiring Diagram with TC Jack Panel, SO Cord |
SOFTWARE (BY CONTROLLER MANUFACTURER)
|
Download Controller Software (Windows Only) Shift Controls does not support this software, it is developed and distributed by the controller manufacturer |